BrightLine
ZERO – for “zero-pixel-shift” imaging |
Semrock
has uniquely solved the problem of poor image registration!
|
All BrightLine®
single-band filter sets are available with certified “zero-pixel-shift”
performance, allowing you to make perfect multi-color composite
images. Just choose the BrightLine ZERO option – only $99
more than the price of the already amazing BrightLine filters! With
BrightLine ZERO no special assembly or orientation of the filters
is required to eliminate the pixel shift problem – the phenomenal
performance is guaranteed by the filters themselves!
BrightLine ZERO sets are ideal for demanding applications like:
|
|
To order,
simply append “–ZERO” to the part number of standard
BrightLine single-band catalog filter sets and add ONLY $99! Delivery
is generally from stock.
Future-proof
your system –
since these filters do not burn out you may be using them for
a very long time. So even if you don't need "zero pixel shift"
today, at this low price you can afford to add this feature just in
case!
Image
Registration Specifications for Microscopy – as tested with
popular Leica, Nikon, Olympus, and Zeiss microscope cubes.
| Property |
Value |
Comments |
| Set-to-set
Pixel Shift |
<
± 1 pixel |
Relative
pixel shift among BrightLine ZERO filter sets, based on state-of-the-art
6.7 µm pixel size (and all larger pixel sizes) and with a
200 mm focal length tube lens [1] |
Note: performance
is only specified relative to other BrightLine ZERO™ filter sets.
How do we do it?
Poor
image registration, or pixel shift, results
from the almost inevitable non-zero filter wedge angle. But low pixel
shift is critical to obtain the best imaging performance when exchanging
filters during any measurements that involve multiple exposures.
Semrock’s
advanced ion-beam sputtering (IBS) coating technology makes
it possible for all BrightLine
filters to be uniquely constructed from a single piece of glass,
with the permanent hard coatings applied directly to the outside.
This patented [2] lower-loss and high-reliability construction
inherently offers superior imaging performance. BrightLine ZERO
filter substrates
are further manufactured and tested to the most exacting tolerances
for certified "zero-pixel-shift" performance. |
 |
|
| With older soft-core fluorescence filters, one is forced to use
multiple substrates that are typically boned together with adhesive,
generally resulting n significant wedge angle and therefore pixel
shift. To improve the imaging registration, extra processing steps,
alignment steps, and/or compensating optics are required, resulting
in added cost. By contrast, BrightLine ZERO filters are inherently
manufacturable and thus very affordable. |
 |
|
What
is pixel shift?
Pixel shift results
when a filter in an imaging path (the emitter and/or dichroic beamsplitter
in a fluorescence microscope) with a non-zero wedge angle deviates the
light rays so as to cause a shift of the image detected on a high-resolution
CCD camera. When two or more images of the same object acquired using
different filter sets are overlaid (in order to simultaneously view fluorescence
from multiple fluorophores), any significant non-zero filter wedge angle
means that the images will not be registered to identical pixels on the
CCD camera. Hence, images produced by different fluorophores will not
be accurately correlated or combined. On the other hand, BrightLine ZERO
filter sets are manufactured and tested to very tight tolerances so as
to ensure accurate image registration every time.
| This
schematic of a typical epi-fluorescence geometry (as in a standard
microscope) shows how filter wedge causes pixel shift. |
 |
 |
Composite
images produced from conventional filter sets (left), typically having
much greater than 1 pixel shift, are distorted, whereas ZERO pixel
shift filter sets (right) yield precise multi-color images. (Simulation) |
 |
|
 |
[1] Note that BrightLine
ZEROs are designed to achieve the specified zero-pixel-shift performance
in substantially collimated imaging systems, as in most infinity-corrected
epi-fluorescence microscopes. For volume OEM instrumentation applications
that involve non-collimated light, contact us directly with your requirements
(filters@semrock.com or 1-866-SEMROCK).
[2]
U.S. Patent No. 6,809,859 and pending. |